With traceable calibration, nobody independent checks the supplier, so you cannot know what you are getting. This guide explains what UKAS accreditation verifies, and why that work is reflected in the price.
With traceable, you do not know what you are getting
This is the most important difference, and the one most often missed. Nobody independent audits a company that offers traceable calibration. Its methods, reference equipment, staff and results are checked by no one but itself.
Even the word traceable leaves the key questions unanswered. Traceable to what? Was the reference equipment itself calibrated by an accredited laboratory, and is it still in date? How was your instrument compared with it: in a controlled bath or chamber, at which points, with how long to stabilise, and with what uncertainty? A traceable certificate rarely says. Without those answers, the link back to national standards is a claim, not evidence. Every supplier applies the word in its own way, so two traceable certificates can mean completely different things. Examine any traceable claim closely and it soon falls apart, unless the work was done to a recognised standard. ISO/IEC 17025 is that standard, and UKAS accreditation is the independent proof that it has been met.
That company may be very good. It may be very poor. From the certificate alone, you cannot tell which. The only way to find out is to audit the supplier yourself: examine its procedures, reference equipment, calibration records, uncertainty calculations and training files, and have the technical knowledge to judge them. Few customers have the time or expertise to do that, and fewer still do it every year.
UKAS accreditation does that work for you. Independent assessors audit an accredited laboratory against ISO/IEC 17025 every year, so the competence behind the certificate has already been verified before you place an order.
The question we get asked
“Why is your UKAS calibration more expensive than the company we currently use?” It is a fair question, and one we hear often.
The short answer: a UKAS accredited calibration and a “traceable” calibration are not the same thing. The certificates can look alike, except ours carries the UKAS logo, but the work behind them is very different.
The extra cost pays for a quality system that is independently audited, a measurement uncertainty that is calculated and stated, and a routine of checks that proves our results are right every day.
Below we explain where that cost goes, so you can decide which service your process really needs.
What UKAS accreditation to ISO/IEC 17025 really means
UKAS (the United Kingdom Accreditation Service) is the sole national accreditation body recognised by the UK government. ISO/IEC 17025 is the international standard that sets out how a calibration laboratory must prove it is competent and that its results are valid.
Accreditation is not a blanket badge. Each accredited laboratory has a published Schedule of Accreditation that lists exactly which measurements it is approved for, over which ranges, and the smallest uncertainty it can claim. Only calibrations inside that schedule can carry the UKAS mark.
TekTroniks is UKAS accredited calibration laboratory No. 9531. Our schedule covers temperature and relative humidity calibration, both in our Cotgrave laboratory and on customers’ sites. It also covers temperature mapping of chambers, fridges, freezers, cold rooms and warehouses. You can see our current Schedule of Accreditation on the UKAS website.
Because UKAS is part of the international ILAC agreement, a UKAS certificate is accepted by auditors, regulators and customers around the world. By contrast, the word “traceable” is easy to claim. It has a strict definition in international metrology, but outside accreditation nobody independent checks that a supplier meets it. Any company can print it on a certificate.
1. Independent auditing, every year
A UKAS laboratory is assessed by people independent of the laboratory, appointed by UKAS. Each visit is led by a UKAS lead assessor, supported by technical assessors who are experts in the measurements being checked.
Assessors do not just read our paperwork. They:
- watch our technicians carry out real calibrations, start to finish
- pull certificates at random and trace every figure back to the raw data
- check our uncertainty calculations, equipment records and training files
- review our complaints, internal audits and corrective actions
There are surveillance visits every year and a full reassessment on a four yearly cycle. Any finding must be fixed, with evidence, within a set deadline, or accreditation is at risk. On top of that, we run an internal audit programme and management reviews.
All of this costs money: UKAS assessment fees and annual charges, plus the staff time to prepare for and support each visit. A non accredited supplier has none of these costs, because nobody checks their work.
2. Traceability you can prove
True traceability is an unbroken chain of calibrations, from your instrument back to national standards such as those held at the National Physical Laboratory (NPL). Every link in that chain must be documented and must state its own uncertainty.
Our reference standards are calibrated by UKAS accredited laboratories or by a national measurement institute. Recall intervals are set from each instrument’s drift history, not chosen to save money. Each reference must also be calibrated across the full range we use it for.
This is not one or two instruments. We run and maintain a large fleet of reference equipment: multiple reference thermometers, liquid and dry block baths, and climatic chambers. Every item has its own calibration history, recall date, check records and uncertainty contribution, and every item must be kept in service, in date and within limits.
Many “traceable” certificates simply quote a reference instrument’s serial number. They often cannot show whether that instrument was itself accredited, in date, or calibrated at the points that matter. Keeping a fully traceable set of high grade reference equipment is one of the biggest running costs of an accredited laboratory.
3. A calculated uncertainty on every result
No measurement is perfect. A UKAS certificate tells you how good each result is, by stating its measurement uncertainty, normally at a 95% confidence level.
Our best uncertainties are published on our UKAS schedule. For example, 0.10 °C for temperature loggers and indicators from −45 °C to +50 °C in a block bath, and 0.15 °C for fixed probes calibrated in situ from −30 °C to +55 °C. We are not allowed to quote anything smaller on a UKAS certificate.
To get that figure, we build an uncertainty budget for every type of calibration, following UKAS guidance (M3003). Each budget adds up every source of doubt, for example:
- the uncertainty of our reference standard, from its own certificate
- how far the reference may have drifted since it was last calibrated
- the stability and uniformity of the bath or chamber used
- the resolution and repeatability of your instrument
- effects such as immersion depth, self heating and hysteresis
These are combined and expanded as follows, where k is usually 2:
U = k × √[ Σ (cᵢ × uᵢ)² ]
Every budget is reviewed by UKAS technical assessors. This matters to you because a pass or fail is only meaningful if the uncertainty is known. If your probe must read within ±0.5 °C, an unstated uncertainty of ±0.4 °C would make a “pass” almost worthless. ISO/IEC 17025 also requires us to agree a decision rule with you before stating pass or fail.
4. Technicians authorised calibration by calibration
In an accredited laboratory, being employed is not the same as being allowed to calibrate. Each technician is trained against our written procedures, works under supervision, and is then formally authorised for each specific type of calibration. Authorisation only follows once they have shown, with recorded evidence, that they get the right answer each and every time they undertake work.
Competence is then monitored on an ongoing basis. UKAS assessors check the training records and watch authorised staff at work. When methods or equipment change, staff are retrained and reauthorised.
Training time is time not spent on paid work. It is a real cost, and it is a big part of why you can trust that whoever calibrates your equipment knows exactly what they are doing.
5. Checking our results against other labs, and each other
ISO/IEC 17025 requires a laboratory to prove its results stay valid. We do this in two ways.
Inter laboratory comparisons and proficiency testing. A reference item is sent round a group of laboratories, and each calibrates it without knowing the expected answer. Results are scored against a reference value using a statistic called the En number. A score between −1 and +1 shows our result agrees within our stated uncertainty. Anything outside that range must be investigated and put right. UKAS expects accredited labs to take part in these schemes for the measurements on their schedule.
Inter technician comparisons. Inside the lab, different technicians calibrate the same item, and the results are compared. This shows that your result does not depend on who happened to do the work.
External calibration fees, shipping of reference items and the time spent are all extra costs. A non accredited supplier has no obligation to compare its results with anyone.
6. Monthly checks on all reference equipment
An annual calibration certificate only tells you how an instrument performed on one day. Between calibrations, our reference equipment is checked every month.
These intermediate checks include cross checking reference instruments against each other and against fixed reference points. Every result is recorded and plotted over time, so any drift shows up long before it becomes a problem.
If a check fails, the instrument is taken out of use at once. We then assess every calibration it was used for since its last good check, and contact any customer whose results could be affected. This routine takes skilled time every month, but it means a fault cannot sit unnoticed for a year.
7. Mapped baths and chambers
Most temperature and humidity calibrations compare your instrument with our reference inside a liquid bath, dry block or climatic chamber. That only works if both sensors see the same conditions.
No bath or chamber is perfectly even or perfectly steady. So we map each one with multiple sensors across its working space, at the set points we use, to measure its uniformity and stability. Mapping is repeated at set intervals, and the results feed straight into our uncertainty budgets.
Many traceable services simply assume the bath is uniform. Yet the difference between two points in a poorly characterised chamber can be larger than the tolerance you are trying to check. Mapping takes time, extra sensors and analysis, but without it the result on the certificate cannot be relied on.
8. Two reference thermometers on every calibration
Our defined calibration process uses two independent reference thermometers on every calibration, not one.
The two references act as a constant check on each other. If they ever disagree by more than expected, we know straight away that something is wrong, and the calibration is stopped before a result is issued. With a single reference, a drifting or damaged thermometer can pass its error on to every instrument it calibrates, and nobody would know.
It means buying, calibrating and checking twice as many reference thermometers. We think that is a price worth paying for results you can rely on.
UKAS accredited vs traceable: side by side
| UKAS accredited (ISO/IEC 17025) | “Traceable” calibration | |
|---|---|---|
| Independent assessment | Yearly UKAS visits, work witnessed | None required |
| Traceability chain | Unbroken, documented, uncertainty at each step | Claimed, often not provable |
| Measurement uncertainty | Calculated, reviewed, stated on every certificate | Often not stated |
| Pass or fail decision rule | Agreed with you and stated | Usually not defined |
| Technician competence | Authorised per calibration, assessed by UKAS | Internal only, if at all |
| Proficiency testing | Required, results investigated | Not required |
| Reference equipment checks | Monthly, trended, failures investigated | Not required |
| Baths and chambers | Mapped, included in uncertainty | Often assumed uniform |
| Recognition | Accepted worldwide via ILAC | Up to your auditor |
So, is it worth paying more?
It depends on what rides on your measurements. If an instrument is only used as a rough guide, a traceable calibration may be enough.
But many of our customers work in pharmaceuticals, food production, healthcare and warehousing. If your readings protect medicines, food, patients or stored products, or if an auditor, regulator or customer asks for UKAS, the extra cost buys proof, not just paperwork. A cheaper certificate that would not stand up to scrutiny can cost far more in failed audits, rejected stock or product recalls.
When you compare quotes, ask the other supplier three questions: Is the calibration on a UKAS schedule? Is the uncertainty stated? Who checks your work?
For how the same principles apply to mapping, see our guide to temperature mapping requirements and accredited mapping.
If you would like to talk through what your equipment really needs, we will tell you honestly whether UKAS accredited calibration is required for your application. Call us on 0115 989 0090, email [email protected], or get in touch through our website.
UKAS calibration FAQs
What is the difference between UKAS accredited and traceable calibration?
A UKAS accredited calibration is carried out within a laboratory’s ISO/IEC 17025 Schedule of Accreditation, under a process independently assessed by UKAS, with a calculated measurement uncertainty on every certificate. A “traceable” claim outside accreditation is not independently checked, and every supplier applies the word in its own way.
Is traceable calibration always worse?
Not necessarily. Some traceable suppliers do good work. The problem is that nobody independent audits them, so you cannot know which you are getting unless you audit them yourself.
Why does UKAS calibration cost more?
The cost covers independent UKAS assessment, a fully traceable fleet of reference equipment, uncertainty budgets for every type of calibration, authorised technicians, proficiency testing and monthly checks of reference equipment.
What is measurement uncertainty?
It is the range either side of a result within which the true value is expected to lie, normally stated at a 95% confidence level. A pass or fail is only meaningful if the uncertainty is known.
What should I ask a calibration supplier?
Is the calibration on a UKAS schedule? Is the uncertainty stated? Who checks your work?